MAINTENANCE
D100 86038260 05/21/07
4-3
!
WARNING:
SOLUTION PUMP REPLACEMENT
1. Turn off all switches and unplug the machine.
2. Remove recovery tank.
3. Remove solution hoses from fittings in pump.
4. Remove the (2) screws that fasten the pump to the frame.
5. Reverse process to install pump.
Pump Head Replacement
65187
Valve Asm
84161
Diaphram
29206
PUMP REPLACEMENT PARTS FOR SHURFLO 100 PSI (86201430 - PRV NO. 250-64A)
ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO
PERFORM THE FOLLOWING REPAIRS.
PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI (86251110 – PRV NO. 65219)
Pump Head Replacement
86251040
PRV NO. 65187
Valve Asm
86258830
PRV NO. 84161
Diaphragm
86235100
PRV NO. 29206
Diaphragm
86235120
PRV NO. 29219
86258860
PRV NO. 84166
VALVE ASM
86251090
PRV NO. 65204
PUMP HEAD
86247360
PRV NO. 53245
MOTOR